24 Hour Service

28600 Lorna Avenue, Warren, MI

Central Air Compressor

Serving the industry since 1959


Air Piping Specialists

Central Air Compressor Air Piping Specialists

There are different types of pipe used for air. The recommended use for air is Aluminum Pipe:

Latest technology (are push to connect aluminum pipe) it is light-weight, making it easy to handle compared to schedule 40 or 80 pipe. It is recommended for clean air applications and is non-corrosive.

Other Types of Air Piping 

Stainless Steel - to minimize corrosion has a long and successful history - combines all strength and durability og black pipe. Victaulic fittings are installed with a rubber seal and bolted clamp.

Copper Pipe is commonly recommended for clean air, it works well, and it is expensive.

Black Pipe is the most commonly used pipe - it is strong and durable; but it will produce rust contamination.

Galvanized Pipe: commonly used for water distribution and for general plumbing; galvanized coating resists moisture in compressed air, but pieces of the coating will flake off (not recommended for compressed air).

PVC Pipe - not recommended for compressed air; though readily available and inexpensive. PVC gets brittle over time and can crack, break, or even shatter.

Black Pipe — Warren, MI — Central Air Compressor

Black Pipe

Ball Valves Gate Check & Globes

Galvanized Pipe — Warren, MI — Central Air Compressor

Galvanized Pipe

Mall - C.I. THRD & FLG

PVC Pipe — Warren, MI — Central Air Compressor

PVC Pipe

CPVC S-80 Fittings

Aluminum Piping — Warren, MI — Central Air Compressor

Aluminum Piping by Aircom


EASY

Easy to install thanks to the innovative Quick Line technology, the insertion of the pipes and the use of components in direct connection will allow you to create your plant in a few simple steps.

RELIABLE

The durability of our products combined with their corrosion-free treatments guarantees a unique and comprehensive system. The study of shapes and materials also ensures acceptable pressure drop and no air leaks, thus resulting in an energy saving.

Pipes — Warren, MI — Central Air Compressor

Pipe

CODE ø(4 m - 13 ft) inch
QLTUAL4016 16 1/2”

Pipe – BLUE 

CODE ø(6m - 20 ft) inch
QLTUAL6020 20 3/4”
QLTUAL6025 25 1”
QLTUAL6032 32 1.1/4”
QLTUAL6040 40 1.1/2”
QLTUAL6050 50 2”
QLTUAL6063 63 2.1/2”
QLTUAL6080 80 3”
Coupling — Warren, MI — Central Air Compressor

Coupling 

CODE ø inch
QLMAAL020 20 3/4”
QLMAAL025 25 1”
QLMAAL032 32 1.1/4”
QLMAAL040 40 1.1/2”
QLMAAL050 50 2”
QLMAAL063 63 2.1/2”
QLMAAL080 80 3”
QLMAAL110 110 4”
Elbow — Warren, MI — Central Air Compressor

90° Elbow 

CODE ø inch
QLG090AL020 20 3/4”
QLG090AL025 25 1”
QLG090AL032 32 1.1/4”
QLG090AL040 40 1.1/2”
QLG090AL050 50 2”
QLG090AL063 63 2.1/2”
QLG090AL080 80 3”
QLG090AL110 110 4”
Tee — Warren, MI — Central Air Compressor

Tee

CODE ø inch
QLTEAL020 20 3/4”
QLTEAL025 25 1”
QLTEAL032 32 1.1/4”
QLTEAL040 40 1.1/2”
QLTEAL050 50 2”
QLTEAL063 63 2.1/2”
QLTEAL080 80 3”
QLTEAL110 110 4”
FPT SST QL Ball Valve — Warren, MI — Central Air Compressor

FPT SST QL ball valve 

CODE ø inch
QLVAINOXF025088 25x1” 1”x1”
QLVAINOXF032128 32x1.1/2” 1.1/4“x1.1/2”
QLVAINOXF040128 40x1.1/2” 1.1/2“x1.1/2”
QLVAINOXF050168 50x2” 2“x2”
QLVAINOXF063168 63x2” 2.1/2“x2”
QLVAINOXF080248 80x3” 3“x3”

Infinity Piping


Infinity Piping — Warren, MI — Central Air Compressor

FLOW RATES THROUGH INFINITY PIPING

Pipe Internal Diameter CFM CFM CFM
mm (in.) @ 125psi @ 150psi @ 175psi
20mm (0.75") 36 39 42
25mm (1") 76 81 88
32mm (1.25") 146 158 171
40mm (1.5") 266 291 310
50mm (2") 476 526 565
63mm (2.5") 881 965 1047

Flow rates are based on a 1psi pressure drop per 100ft run of pipe and couplings in a “straight line.” For loop systems, flow rates can be doubled.

Example:

100ft run of 2" pipe flows 476cfm at 125psig with a pressure drop of 1psig. If a system is designed in a loop configuration, a flow of 952cfm with a pressure loss of 1psig per 200ft of piping and couplings can be achieved.The 1psi pressure loss will only occur if the compressor system is flowing the maximum flow capacity of the piping selected.

Flows are measured at standard atmospheric conditions: 1013mbar (14.7psi) at 20°C - (68°F).

It is vital that the size of the piping between the compressors and the connection of the loop system can flow the full capacity of the combined compressor output.

Testing

Infinity tube fittings are tested in accordance with the requirements of ANSI B31.1 (American National Standards Institute) Power Piping Systems. All Infinity products have been tested and exceed the requirements of ANSI B31.1.

Infinity product provides a 5X safety factor above recommended safe working pressure/temperatures.

Women's Business Enterprise
Share by:
Alternatively, AMP Tagging